Functioning ≠ Reliable
A single successful functional test says little about the long-term reliability of a product. A device can function perfectly in the laboratory and still have weaknesses that only become apparent after extended use.
A connector can be subjected to stress from strong or unusual movements. A printed circuit board can be subjected to mechanical stresses. A component can heat up or be subjected to stress over many temperature cycles.
Therefore, during development, we not only ask the question:
„"Does the product work?"“
But also:
„"What could cause it to stop working at some point?"“
This perspective changes the development.
Reliability begins with the design.
Many factors that later determine the lifespan of a product are already determined during the design phase.
These include, for example:
This means that reliability cannot simply be "tested in" at the end of the project.
Tests can show whether a product meets certain requirements. However, the foundation for this is laid during the development process.
What stresses must a medical device withstand?
To develop reliable hardware, we first need to understand what actually happens during later use. A medical device can be exposed to very different stresses depending on its application.
Thermal loads
Electronic components generate heat. At the same time, devices can operate in varying ambient temperatures. Temperature can influence the properties of components and affect the lifespan and function of the overall system. Therefore, how heat is generated, distributed, and dissipated must be considered during the development phase.
Mechanical loads
Shocks, vibrations, movements, or repeated stresses can also affect reliability. This isn't just about obvious mechanical components.
Circuit boards, solder joints, connectors and cables can also be subjected to mechanical stress.
Especially with wearables, the product may be regularly moved, bent, put on and taken off.
Electrical loads
The electrical design also plays an important role.
Voltages, currents, switching processes, tolerances and thermal effects must be suitable for the intended use.
A component that functions under ideal laboratory conditions is not automatically the best choice for a product that is intended to operate under changing conditions for years.
Environmental conditions
Depending on the application, moisture, perspiration, dust, cleaning and disinfection processes, or other environmental factors may also be relevant. Especially with medical devices, such conditions must be considered as early as possible in the development process.
The right component for the right application
Therefore, an important part of Design for Reliability is the selection of suitable components.
This is not just about the question:
„"Does this component meet our specifications?"“
But also:
„"Is this component suitable for our specific application in the long term?"“
In addition to technical data, factors such as temperature range, load capacity, lifespan, manufacturing quality, availability and potential obsolescence can play a role.
Even seemingly small decisions can later have a major impact on a product.
Therefore, the cheapest component is not automatically the most economical solution if it later leads to failures, changes, or additional testing.
Mechanics and electronics must work together.
Furthermore, when developing medical hardware, one should not only consider the individual discipline.
Electronics and mechanics influence each other.
A component can be electrically correctly designed and still be stressed by an unfavorable mechanical design. A cable, for example, can be subjected to stress from repeated movement. A connector can be exposed to mechanical forces. A printed circuit board can deform under certain conditions.
Therefore, we consider the product as a complete system.
The question is not just whether each individual component works.
The crucial question is whether the interaction of the components functions reliably under the intended conditions.
Tolerances
Another important point is tolerances.
During development, typical values are often considered. In reality, however, components and manufacturing processes lie within specific tolerance ranges.
Things will therefore become particularly interesting at the borders:
What happens when multiple components are simultaneously operating at the edge of their specifications?
Such considerations help to identify weaknesses during the development process.
Because a robust design should not only function under ideal conditions, but also be able to cope with permissible deviations.
Good development and good testing go hand in hand.
However, Design for Reliability does not mean that testing becomes unnecessary.
On the contrary.
The development process defines the requirements the product must meet and the conditions under which it should function reliably. Tests then provide the necessary verification.
Depending on the product, functional, electrical, mechanical, or environmental tests may be relevant. Stress and lifetime tests can also be used to identify weaknesses.
For us, the following applies:
A test should not only confirm that everything works. It should help to identify the limits of the design.
The goal is not to conduct as many tests as possible.
The goal is to identify the right risks and mitigate them with appropriate testing.
Reliability is a task of the entire development process.
Ultimately, reliability cannot be reduced to a single development discipline.
It arises from the interplay of many decisions:
Requirements → System architecture → Components → Electronics → Mechanics → Manufacturing → Testing → Validation
If important stresses are not considered in the initial requirements, problems will arise later. If components are unsuitable for the application, even extensive testing will only be of limited help.
And if manufacturing processes cannot reliably reproduce the intended quality, a problem also arises.
Design for Reliability therefore means one thing above all for us:
Consider reliability from the very beginning.
Our approach
Therefore, when developing medical hardware, we do not only consider the functioning prototype.
We ask early:
What stresses occur during later use?
Which components are suitable for this?
Where can mechanical, electrical, or thermal weaknesses arise?
What tolerances need to be taken into account?
And how can we prove, through appropriate tests, that the developed product reliably meets these requirements?
Because good design is not only characterized by the fact that it works.
It is designed to function reliably even when reality does not match perfect laboratory conditions.