{"id":2669,"date":"2019-01-29T16:22:50","date_gmt":"2019-01-29T14:22:50","guid":{"rendered":"http:\/\/medtech-ingenieur.de\/?p=2669"},"modified":"2021-08-06T14:40:34","modified_gmt":"2021-08-06T13:40:34","slug":"wenn-software-auf-qualitaet-s-metriken-trifft-teil-2","status":"publish","type":"post","link":"https:\/\/medtech-ingenieur.de\/en\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/","title":{"rendered":"When software meets quality (s-metrics) \u2013 Part 2"},"content":{"rendered":"<h2>SW metrics from the QMS perspective<\/h2>\n<h3>Why should software quality metrics be used in the product life cycle?<\/h3>\n<p>A software metric maps a software unit into a numerical value. The numerical value represents a measure of the internal quality of software. Software code metrics are used to quantify software properties as quickly as possible. This is done to track a quality measure throughout the product lifecycle and to compare programs using the same or similar programming language.<\/p>\n<p>ISO 13485 and IEC 62304 form the cornerstone of the normative requirements for the development and maintenance of medical software. Depending on the software safety class, the requirements for the development and documentation of safety-critical software become more stringent. ISO 26262-6 applies to the automotive industry and sets out specific requirements for software verification. Tables 14 and 17, among others, list metrics at the software unit and architecture levels. IEC 62304 is less specific in this regard. Nevertheless, metrics can be used to fulfill additional acceptance criteria for software units (Chapter 5.5.4 IEC 62304: 2006) or as a baseline for regression testing and software release readiness. Furthermore, ISO 13485 and 21 CFR 820.250 are very specific regarding the use of statistical methods for assessing product characteristics. Here, software metrics offer a great opportunity to provide quantitative statements and also to quickly and effectively counteract negative trends in software quality.<\/p>\n<h3>Weaknesses of software quality metrics<\/h3>\n<p>Software metrics can only be meaningfully determined using appropriate tools. The operating effort, as well as any licensing costs, must be factored into the project plan. All tools used must be validated for their intended purpose. This effort must also be sensibly planned.<\/p>\n<p>A single metric can never provide a complete statement about software quality. Metrics should always be evaluated in combination. The quality and maturity of software can only be definitively assessed in combination with static code analysis, code reviews, and functional tests. Software metrics should not be created at the end of development to satisfy the auditor, but rather should be used continuously throughout the product lifecycle to sustainably improve the readability and maintainability of source code.<\/p>\n<h3>To use<\/h3>\n<p>If the tools are validated and operational, software metrics can be easily integrated into the development and maintenance process. This helps, among other things, to detect potential bugs early on, rather than having to wait much later through laborious system-level debugging sessions. The investment in licensing costs can therefore pay for itself very quickly.<\/p>\n<p>Key performance indicators are useful where a quantitative analysis of software properties is appropriate. This is the case for software properties according to ISO 25010 in the areas of maintainability, efficiency, security, and reliability. Other properties such as functionality, usability, compatibility, and portability can only be verified using appropriate testing methods.<\/p>\n<p>Software metrics can be used as a tool in the field of data analysis (Chapter 8.4 ISO 13485:2016) to determine product characteristics and their trends. This provides the opportunity to counteract negative trends and, at the same time, to implement a general mechanism for improvement. Regulatory-required key performance indicators can be easily, objectively, and efficiently integrated into the process using software metrics.<\/p>\n<p>The use and tracking of software metrics even after the product release can help make the code more robust, increase maintainability and overall contribute to customer satisfaction and secure software.<\/p>\n<h3>Literature, links and training<strong><br \/>\n<\/strong><\/h3>\n<ul>\n<li>Basics of Software Testing \u2013 Andreas Spillner and Tilo Linz<\/li>\n<li>Software testing for embedded systems \u2013 Stephan Gr\u00fcnfelder<\/li>\n<li>Basic knowledge of medical software \u2013 Christian Johner, Matthias H\u00f6lzer-Kl\u00fcpfel and Sven Wittorf<\/li>\n<li>Certification: ISTQB Certified Tester<\/li>\n<li>Certification: Certified Professional for medical software<\/li>\n<li>Embarc, Architecture Spicker \u2013 quantitative analysis: (https:\/\/www.embarc.de\/architektur-spicker\/)<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>SW-Metriken aus Sicht des QMS Warum sollen Software Qualit\u00e4tsmetriken im Produktlebenszyklus eingesetzt werden? Eine Softwaremetrik bildet eine Software-Einheit in einen Zahlenwert ab. Der Zahlenwert steht f\u00fcr ein Ma\u00df f\u00fcr die innere Qualit\u00e4t von Software. Software Code Metriken werden eingesetzt, um in m\u00f6glichst kurzer Zeit Eigenschaften von Software quantifizieren zu k\u00f6nnen. Zum einen, um ein Qualit\u00e4tsma\u00df [&hellip;]<\/p>\n","protected":false},"author":14,"featured_media":2856,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[9,6],"tags":[300,299,132,298,31,296,32],"class_list":["post-2669","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-gastblogs","category-software","tag-iec","tag-iec62304","tag-iso","tag-iso13485","tag-qms","tag-qualitaet","tag-qualitaetsmanagement","post-wrapper","thrv_wrapper"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Wenn Software auf Qualit\u00e4t (s-Metriken) trifft \u2013 Teil 2 - MEDtech Ingenieur GmbH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/medtech-ingenieur.de\/en\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Wenn Software auf Qualit\u00e4t (s-Metriken) trifft \u2013 Teil 2 - MEDtech Ingenieur GmbH\" \/>\n<meta property=\"og:description\" content=\"SW-Metriken aus Sicht des QMS Warum sollen Software Qualit\u00e4tsmetriken im Produktlebenszyklus eingesetzt werden? Eine Softwaremetrik bildet eine Software-Einheit in einen Zahlenwert ab. Der Zahlenwert steht f\u00fcr ein Ma\u00df f\u00fcr die innere Qualit\u00e4t von Software. Software Code Metriken werden eingesetzt, um in m\u00f6glichst kurzer Zeit Eigenschaften von Software quantifizieren zu k\u00f6nnen. Zum einen, um ein Qualit\u00e4tsma\u00df [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/medtech-ingenieur.de\/en\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/\" \/>\n<meta property=\"og:site_name\" content=\"MEDtech Ingenieur GmbH\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/medtechIngenieur\" \/>\n<meta property=\"article:published_time\" content=\"2019-01-29T14:22:50+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-08-06T13:40:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/medtech-ingenieur.de\/wp-content\/uploads\/2018\/12\/survey-3957027_960_720.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"960\" \/>\n\t<meta property=\"og:image:height\" content=\"557\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"(Gast) Carina Schmitz\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@MedtechIng\" \/>\n<meta name=\"twitter:site\" content=\"@MedtechIng\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"(Gast) Carina Schmitz\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\\\/\"},\"author\":{\"name\":\"(Gast) Carina Schmitz\",\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/#\\\/schema\\\/person\\\/6c289ce31072730d50cfec7df1057a8d\"},\"headline\":\"Wenn Software auf Qualit\u00e4t (s-Metriken) trifft \u2013 Teil 2\",\"datePublished\":\"2019-01-29T14:22:50+00:00\",\"dateModified\":\"2021-08-06T13:40:34+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\\\/\"},\"wordCount\":625,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wp-content\\\/uploads\\\/2018\\\/12\\\/survey-3957027_960_720.jpg\",\"keywords\":[\"IEC\",\"IEC62304\",\"ISO\",\"ISO13485\",\"QMS\",\"Qualit\u00e4t\",\"Qualit\u00e4tsmanagement\"],\"articleSection\":[\"Gastblogs\",\"Software\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/medtech-ingenieur.de\\\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\\\/\",\"url\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\\\/\",\"name\":\"Wenn Software auf Qualit\u00e4t (s-Metriken) trifft \u2013 Teil 2 - MEDtech Ingenieur GmbH\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wp-content\\\/uploads\\\/2018\\\/12\\\/survey-3957027_960_720.jpg\",\"datePublished\":\"2019-01-29T14:22:50+00:00\",\"dateModified\":\"2021-08-06T13:40:34+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/medtech-ingenieur.de\\\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wp-content\\\/uploads\\\/2018\\\/12\\\/survey-3957027_960_720.jpg\",\"contentUrl\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wp-content\\\/uploads\\\/2018\\\/12\\\/survey-3957027_960_720.jpg\",\"width\":960,\"height\":557,\"caption\":\"quality\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/medtech-ingenieur.de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wenn Software auf Qualit\u00e4t (s-Metriken) trifft \u2013 Teil 2\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/#website\",\"url\":\"https:\\\/\\\/medtech-ingenieur.de\\\/\",\"name\":\"MEDtech Ingenieur GmbH\",\"description\":\"Ingenieursdienstleister f\u00fcr Medizintechnik\",\"publisher\":{\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/#organization\"},\"alternateName\":\"MEDtech\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/medtech-ingenieur.de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/#organization\",\"name\":\"MEDtech Ingenieur\",\"alternateName\":\"MEDtech\",\"url\":\"https:\\\/\\\/medtech-ingenieur.de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/logo-700x700-1.png\",\"contentUrl\":\"https:\\\/\\\/medtech-ingenieur.de\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/logo-700x700-1.png\",\"width\":700,\"height\":700,\"caption\":\"MEDtech Ingenieur\"},\"image\":{\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/medtechIngenieur\",\"https:\\\/\\\/x.com\\\/MedtechIng\",\"https:\\\/\\\/www.instagram.com\\\/medtech.ingenieure\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/37871229\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/medtech-ingenieur.de\\\/#\\\/schema\\\/person\\\/6c289ce31072730d50cfec7df1057a8d\",\"name\":\"(Gast) Carina Schmitz\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f090fe14e43c33695e80c7000a932c1a3eeff5aecbc5b0f4494513c5b16e9709?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f090fe14e43c33695e80c7000a932c1a3eeff5aecbc5b0f4494513c5b16e9709?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f090fe14e43c33695e80c7000a932c1a3eeff5aecbc5b0f4494513c5b16e9709?s=96&d=mm&r=g\",\"caption\":\"(Gast) Carina Schmitz\"},\"description\":\"Carina Schmitz ist Ingenieurin der Medizintechnik und Consultant bei be-on-Quality GmbH. Ihre Aufgaben umfassen dabei die Betreuung von Kunden rund um Qualit\u00e4tsmanagementsysteme (ISO 13485, 21CFR820) und Zulassungsstrategien von Medizinprodukten. Durch langj\u00e4hrige Erfahrung im Bereich Verifikation und Validierung, besteht ein gro\u00dfes Verst\u00e4ndnis von Entwicklungsaufgaben und deren Prozesssteuerung. Die kontinuierliche Verbesserung von Unternehmensabl\u00e4ufen durch die qualifizierte Durchf\u00fchrung von internen Audits und Inspektionen rundet das Profil ab.\",\"sameAs\":[\"http:\\\/\\\/www.be-on-quality.com\"],\"url\":\"https:\\\/\\\/medtech-ingenieur.de\\\/en\\\/author\\\/carina\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"When software meets quality (s-metrics) \u2013 Part 2 - MEDtech Ingenieur GmbH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/medtech-ingenieur.de\/en\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/","og_locale":"en_US","og_type":"article","og_title":"Wenn Software auf Qualit\u00e4t (s-Metriken) trifft \u2013 Teil 2 - MEDtech Ingenieur GmbH","og_description":"SW-Metriken aus Sicht des QMS Warum sollen Software Qualit\u00e4tsmetriken im Produktlebenszyklus eingesetzt werden? Eine Softwaremetrik bildet eine Software-Einheit in einen Zahlenwert ab. Der Zahlenwert steht f\u00fcr ein Ma\u00df f\u00fcr die innere Qualit\u00e4t von Software. Software Code Metriken werden eingesetzt, um in m\u00f6glichst kurzer Zeit Eigenschaften von Software quantifizieren zu k\u00f6nnen. Zum einen, um ein Qualit\u00e4tsma\u00df [&hellip;]","og_url":"https:\/\/medtech-ingenieur.de\/en\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/","og_site_name":"MEDtech Ingenieur GmbH","article_publisher":"https:\/\/www.facebook.com\/medtechIngenieur","article_published_time":"2019-01-29T14:22:50+00:00","article_modified_time":"2021-08-06T13:40:34+00:00","og_image":[{"width":960,"height":557,"url":"https:\/\/medtech-ingenieur.de\/wp-content\/uploads\/2018\/12\/survey-3957027_960_720.jpg","type":"image\/jpeg"}],"author":"(Gast) Carina Schmitz","twitter_card":"summary_large_image","twitter_creator":"@MedtechIng","twitter_site":"@MedtechIng","twitter_misc":{"Written by":"(Gast) Carina Schmitz","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/medtech-ingenieur.de\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/#article","isPartOf":{"@id":"https:\/\/medtech-ingenieur.de\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/"},"author":{"name":"(Gast) Carina Schmitz","@id":"https:\/\/medtech-ingenieur.de\/#\/schema\/person\/6c289ce31072730d50cfec7df1057a8d"},"headline":"Wenn Software auf Qualit\u00e4t (s-Metriken) trifft \u2013 Teil 2","datePublished":"2019-01-29T14:22:50+00:00","dateModified":"2021-08-06T13:40:34+00:00","mainEntityOfPage":{"@id":"https:\/\/medtech-ingenieur.de\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/"},"wordCount":625,"commentCount":0,"publisher":{"@id":"https:\/\/medtech-ingenieur.de\/#organization"},"image":{"@id":"https:\/\/medtech-ingenieur.de\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/#primaryimage"},"thumbnailUrl":"https:\/\/medtech-ingenieur.de\/wp-content\/uploads\/2018\/12\/survey-3957027_960_720.jpg","keywords":["IEC","IEC62304","ISO","ISO13485","QMS","Qualit\u00e4t","Qualit\u00e4tsmanagement"],"articleSection":["Gastblogs","Software"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/medtech-ingenieur.de\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/medtech-ingenieur.de\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/","url":"https:\/\/medtech-ingenieur.de\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/","name":"When software meets quality (s-metrics) \u2013 Part 2 - MEDtech Ingenieur GmbH","isPartOf":{"@id":"https:\/\/medtech-ingenieur.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/medtech-ingenieur.de\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/#primaryimage"},"image":{"@id":"https:\/\/medtech-ingenieur.de\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/#primaryimage"},"thumbnailUrl":"https:\/\/medtech-ingenieur.de\/wp-content\/uploads\/2018\/12\/survey-3957027_960_720.jpg","datePublished":"2019-01-29T14:22:50+00:00","dateModified":"2021-08-06T13:40:34+00:00","breadcrumb":{"@id":"https:\/\/medtech-ingenieur.de\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/medtech-ingenieur.de\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/medtech-ingenieur.de\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/#primaryimage","url":"https:\/\/medtech-ingenieur.de\/wp-content\/uploads\/2018\/12\/survey-3957027_960_720.jpg","contentUrl":"https:\/\/medtech-ingenieur.de\/wp-content\/uploads\/2018\/12\/survey-3957027_960_720.jpg","width":960,"height":557,"caption":"quality"},{"@type":"BreadcrumbList","@id":"https:\/\/medtech-ingenieur.de\/wenn-software-auf-qualitaet-s-metriken-trifft-teil-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/medtech-ingenieur.de\/"},{"@type":"ListItem","position":2,"name":"Wenn Software auf Qualit\u00e4t (s-Metriken) trifft \u2013 Teil 2"}]},{"@type":"WebSite","@id":"https:\/\/medtech-ingenieur.de\/#website","url":"https:\/\/medtech-ingenieur.de\/","name":"MEDtech Ingenieur GmbH","description":"Engineering service provider for medical technology","publisher":{"@id":"https:\/\/medtech-ingenieur.de\/#organization"},"alternateName":"MEDtech","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/medtech-ingenieur.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/medtech-ingenieur.de\/#organization","name":"MEDtech Engineer","alternateName":"MEDtech","url":"https:\/\/medtech-ingenieur.de\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/medtech-ingenieur.de\/#\/schema\/logo\/image\/","url":"https:\/\/medtech-ingenieur.de\/wp-content\/uploads\/2024\/01\/logo-700x700-1.png","contentUrl":"https:\/\/medtech-ingenieur.de\/wp-content\/uploads\/2024\/01\/logo-700x700-1.png","width":700,"height":700,"caption":"MEDtech Ingenieur"},"image":{"@id":"https:\/\/medtech-ingenieur.de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/medtechIngenieur","https:\/\/x.com\/MedtechIng","https:\/\/www.instagram.com\/medtech.ingenieure\/","https:\/\/www.linkedin.com\/company\/37871229\/"]},{"@type":"Person","@id":"https:\/\/medtech-ingenieur.de\/#\/schema\/person\/6c289ce31072730d50cfec7df1057a8d","name":"(Guest) Carina Schmitz","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/f090fe14e43c33695e80c7000a932c1a3eeff5aecbc5b0f4494513c5b16e9709?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f090fe14e43c33695e80c7000a932c1a3eeff5aecbc5b0f4494513c5b16e9709?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f090fe14e43c33695e80c7000a932c1a3eeff5aecbc5b0f4494513c5b16e9709?s=96&d=mm&r=g","caption":"(Gast) Carina Schmitz"},"description":"Carina Schmitz is a medical technology engineer and consultant at be-on-Quality GmbH. Her responsibilities include supporting clients with quality management systems (ISO 13485, 21CFR820) and approval strategies for medical devices. Her extensive experience in verification and validation has provided her with a thorough understanding of development tasks and their process management. Continuous improvement of company processes through the professional conduct of internal audits and inspections rounds out her profile.","sameAs":["http:\/\/www.be-on-quality.com"],"url":"https:\/\/medtech-ingenieur.de\/en\/author\/carina\/"}]}},"_links":{"self":[{"href":"https:\/\/medtech-ingenieur.de\/en\/wp-json\/wp\/v2\/posts\/2669","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/medtech-ingenieur.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/medtech-ingenieur.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/medtech-ingenieur.de\/en\/wp-json\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/medtech-ingenieur.de\/en\/wp-json\/wp\/v2\/comments?post=2669"}],"version-history":[{"count":11,"href":"https:\/\/medtech-ingenieur.de\/en\/wp-json\/wp\/v2\/posts\/2669\/revisions"}],"predecessor-version":[{"id":5836,"href":"https:\/\/medtech-ingenieur.de\/en\/wp-json\/wp\/v2\/posts\/2669\/revisions\/5836"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/medtech-ingenieur.de\/en\/wp-json\/wp\/v2\/media\/2856"}],"wp:attachment":[{"href":"https:\/\/medtech-ingenieur.de\/en\/wp-json\/wp\/v2\/media?parent=2669"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/medtech-ingenieur.de\/en\/wp-json\/wp\/v2\/categories?post=2669"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/medtech-ingenieur.de\/en\/wp-json\/wp\/v2\/tags?post=2669"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}